[File] DescText = "1769sc-IF8U EDS File"; CreateDate = 12-18-2003; CreateTime = 09:25:00; ModDate = 01-25-2002; ModTime = 12:00:00; Revision = 1.100; $ HomeURL = "http://www.ab.com/networks/eds/XX/0001000A00240100.eds"; [Device] VendCode = 58; VendName = "Spectrum Controls, Inc."; ProdType = 10; ProdTypeStr = "Universal Analog Input"; ProdCode = 41; MajRev = 1; MinRev = 3; ProdName = "1769-8 Channel Analog Universal"; Catalog = "1769sc-IF8U"; Icon = "1769-Brown.ico"; [Modular] Rack1 = 1,108,91,1,1,,,, 1, 2, 3, 4, 5, 6, 7, 8, 9,10, $ Legal slots 11,12,13,14,15,16,17,18,19,20, 21,22,23,24,25,26,27,28,29,30, 31,32,33,34,35,36,37; ExternalID = "3A 00 0A 00 29 00 01"; [1_1769Audit] 1_5vdcPwrLoad = 100; 1_24vdcPwrLoad = 40; 1_DistRating = 8; [Params] ProxiedParam4 = ,,,,,,"","","",0,11,11,,,,,,,,,; $ Input data size ProxiedEnum4 = 0,"No Input Data",1,"Chan. 0 (1 WORD)",2,"Chan. 0-1 (2 WORDS)",3,"Chan. 0-2 (3 WORDS)", 4,"Chan. 0-3 (4 WORDS)",5,"Chan. 0-4 (5 WORDS)",6,"Chan. 0-5 (6 WORDS)",7,"Chan. 0-6 (7 WORDS)",8,"Chan. 0-7 (8 WORDS)",9,"General/open-circuit status",10,"Over/Under-Range Status",11,"CJC Status"; ProxiedParam6 = ,,,,,,"","","",0,2,2,,,,,,,,,; $ Electronic Keying ProxiedEnum6 = 0,"Disable Keying", 1,"Exact Match",2,"Compatible Module"; ProxiedParam7 = ,,,,,,"","","",1,255,1,,,,,,,,,; $ Configured Minor Revision ProxiedParam8 = ,,,,,,"","","",1,255,1,,,,,,,,,; $ Actual Minor Revision $*********************************** $ Input array data $*********************************** Param20= ,,,0x0010, 0xC7, 2, $ UINT "Input Chan. 0 Data","", "WORD 0 - Contains the analog input value.", 0,0xFFFF,0,,,,,,,,,; Param21= ,,,0x0010, 0xC7, 2, $ UINT "Input Chan. 1 Data","", "WORD 1 - Contains the analog input value.", 0,0xFFFF,0,,,,,,,,,; Param22= ,,,0x0010, 0xC7, 2, $ UINT "Input Chan. 2 Data","", "WORD 2 - Contains the analog input value.", 0,0xFFFF,0,,,,,,,,,; Param23= ,,,0x0010, 0xC7, 2, $ UINT "Input Chan. 3 Data","", "WORD 3 - Contains the analog input value.", 0,0xFFFF,0,,,,,,,,,; Param24= ,,,0x0010, 0xC7, 2, $ UINT "Input Chan. 4 Data","", "WORD 4 - Contains the analog input value.", 0,0xFFFF,0,,,,,,,,,; Param25= ,,,0x0010, 0xC7, 2, $ UINT "Input Chan. 5 Data","", "WORD 5 - Contains the analog input value.", 0,0xFFFF,0,,,,,,,,,; Param26= ,,,0x0010, 0xC7, 2, $ UINT "Input Chan. 6 Data","", "WORD 6 - Contains the analog input value.", 0,0xFFFF,0,,,,,,,,,; Param27= ,,,0x0010, 0xC7, 2, $ UINT "Input Chan. 7 Data","", "WORD 7 - Contains the analog input value.", 0,0xFFFF,0,,,,,,,,,; Param28= ,,,0x0010, 0xD2,2, $ WORD "General & Open-circuit Status","", "WORD 8 - Bits 0-7 - When a bit is set (1) an error exists for that corresponding channel. Bits 8-15 - When a bit is set (1) an open input circuit is detected for that corresponding channel.", 0,0xFFFF,0,,,,,,,,,; Enum28 = 0,"Chan. 0 General Status", 1,"Chan. 1 General Status", 2,"Chan. 2 General Status", 3,"Chan. 3 General Status", 4,"Chan. 4 General Status", 5,"Chan. 5 General Status", 6,"Chan. 6 General Status", 7,"Chan. 7 General Status", 8,"Chan. 0 Open-circuit Detection", 9,"Chan. 1 Open-circuit Detection", 10,"Chan. 2 Open-circuit Detection", 11,"Chan. 3 Open-circuit Detection", 12,"Chan. 4 Open-circuit Detection", 13,"Chan. 5 Open-circuit Detection", 14,"Chan. 6 Open-circuit Detection", 15,"Chan. 7 Open-Circuit Detection"; Param29= ,,,0x0010, 0xD2, 2, $ WORD "Over/Under Range Status","", "WORD 9 - Under-range flag bits for channels 0 through 7. Over-range flag bits for channels 0 through 7.", 0,0xFFFF,0,,,,,,,,,; Enum29 = 0, "Chan. 0 Over-range flag", 1, "Chan. 0 Under-range flag", 2, "Chan. 1 Over-range flag", 3, "Chan. 1 Under-range flag", 4, "Chan. 2 Over-range flag", 5, "Chan. 2 Under-range flag", 6, "Chan. 3 Over-range flag", 7, "Chan. 3 Under-range flag", 8, "Chan. 4 Over-range flag", 9, "Chan. 4 Under-range flag", 10,"Chan. 5 Over-range flag", 11,"Chan. 5 Under-range flag", 12,"Chan. 6 Over-range flag", 13,"Chan. 6 Under-range flag", 14,"Chan. 7 Over-range flag", 15,"Chan. 7 Under-range flag"; Param30= ,,,0x0010, 0xD2, 2, $ WORD "CJC Status","", "WORD 10 - CJC Value, CJC Open-circuit indication, CJC Under-range and over-range and general status.", 0,0xFFFF,0,,,,,,,,,; Enum30 = 0, "CJC Value Bits 0 to 11", 1, "CJC Value Bits 0 to 11", 2, "CJC Value Bits 0 to 11", 3, "CJC Value Bits 0 to 11", 4, "CJC Value Bits 0 to 11", 5, "CJC Value Bits 0 to 11", 6, "CJC Value Bits 0 to 11", 7, "CJC Value Bits 0 to 11", 8, "CJC Value Bits 0 to 11", 9, "CJC Value Bits 0 to 11", 10,"CJC Value Bits 0 to 11", 11,"CJC Value Bits 0 to 11", 12,"CJC Open-Circuit", 13,"CJC Under-range", 14,"CJC Over-range", 15,"CJC General status"; $*********************************** $ Module Configuration (word 0) $*********************************** Param100= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 0","", "Temperature Units", 0,1,0,,,,,,,,,; Enum100 = 0,"Degrees C", 1,"Degrees F"; Param101= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 1","", "Temperature Units", 0,1,0,,,,,,,,,; Enum101 = 0,"Degrees C", 1,"Degrees F"; Param102= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 2","", "Temperature Units", 0,1,0,,,,,,,,,; Enum102 = 0,"Degrees C", 1,"Degrees F"; Param103= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 3","", "Temperature Units", 0,1,0,,,,,,,,,; Enum103 = 0,"Degrees C", 1,"Degrees F"; Param104= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 4","", "Temperature Units", 0,1,0,,,,,,,,,; Enum104 = 0,"Degrees C", 1,"Degrees F"; Param105= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 5","", "Temperature Units", 0,1,0,,,,,,,,,; Enum105 = 0,"Degrees C", 1,"Degrees F"; Param106= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 6","", "Temperature Units", 0,1,0,,,,,,,,,; Enum106 = 0,"Degrees C", 1,"Degrees F"; Param107= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 7","", "Temperature Units", 0,1,0,,,,,,,,,; Enum107 = 0,"Degrees C", 1,"Degrees F"; Param108= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "CJC","", "Temperature Units", 0,1,0,,,,,,,,,; Enum108 = 0,"Degrees C", 1,"Degrees F"; Param109 = 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "CJC Weighted Profile","", "Disable Profile", 0,1,0, ,,,,,,,,; Enum109 = 0,"Enabled",1,"disabled"; Param110= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "CJC Display","", "CJC Display Enable", 0,1,0,,,,,,,,,; Enum110 = 0,"Disabled", 1,"Enabled"; $*********************************** $ Module Configuration (word 1) $*********************************** Param200= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 0","", "Open Circuit Disable", 0,1,0,,,,,,,,,; Enum200 = 0,"Enabled", 1,"Disabled"; Param201= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 1","", "Open Circuit Disable", 0,1,0,,,,,,,,,; Enum201 = 0,"Enabled", 1,"Disabled"; Param202= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 2","", "Open Circuit Disable", 0,1,0,,,,,,,,,; Enum202 = 0,"Enabled", 1,"Disabled"; Param203= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 3","", "Open Circuit Disable", 0,1,0,,,,,,,,,; Enum203 = 0,"Enabled", 1,"Disabled"; Param204= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 4","", "Open Circuit Disable", 0,1,0,,,,,,,,,; Enum204 = 0,"Enabled", 1,"Disabled"; Param205= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 5","", "Open Circuit Disable", 0,1,0,,,,,,,,,; Enum205 = 0,"Enabled", 1,"Disabled"; Param206= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 6","", "Open Circuit Disable", 0,1,0,,,,,,,,,; Enum206 = 0,"Enabled", 1,"Disabled"; Param207= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 7","", "Open Circuit Disable", 0,1,0,,,,,,,,,; Enum207 = 0,"Enabled", 1,"Disabled"; Param208= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 0","", "0 Volt CJC Adjust", 0,1,0,,,,,,,,,; Enum208 = 0,"Perform CJC", 1,"No CJC Adjustment"; Param209= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 1","", "0 Volt CJC Adjust", 0,1,0,,,,,,,,,; Enum209 = 0,"Perform CJC", 1,"No CJC Adjustment"; Param210= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 2","", "0 Volt CJC Adjust", 0,1,0,,,,,,,,,; Enum210 = 0,"Perform CJC", 1,"No CJC Adjustment"; Param211= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 3","", "0 Volt CJC Adjust", 0,1,0,,,,,,,,,; Enum211 = 0,"Perform CJC", 1,"No CJC Adjustment"; Param212= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 4","", "0 Volt CJC Adjust", 0,1,0,,,,,,,,,; Enum212 = 0,"Perform CJC", 1,"No CJC Adjustment"; Param213= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 5","", "0 Volt CJC Adjust", 0,1,0,,,,,,,,,; Enum213 = 0,"Perform CJC", 1,"No CJC Adjustment"; Param214= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 6","", "0 Volt CJC Adjust", 0,1,0,,,,,,,,,; Enum214 = 0,"Perform CJC", 1,"No CJC Adjustment"; Param215= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 7","", "0 Volt CJC Adjust", 0,1,0,,,,,,,,,; Enum215 = 0,"Perform CJC", 1,"No CJC Adjustment"; $*********************************** $ Channel 0 configuration data $*********************************** Param300= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 0","", "Enable or Disable Channel 1", 0,1,0,,,,,,,,,; Enum300 = 0,"Enable", 1,"Disable"; Param301 = 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 0 Filter Frequency","", "Set Channel 0 Filter Frequency", 0,6,0, ,,,,,,,,; Enum301 = 2,"10 Hz", 0,"60 Hz", 1,"50 Hz", 3,"250 Hz",4,"500 Hz",5,"1 kHz"; Param302= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 0 Open Circuit","", "Set Channel 0 Open Circuit", 0,3,0,,,,,,,,,; Enum302 = 0,"Upscale", 1,"Downscale", 2,"Last State",3,"Zero"; Param303= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 0 Input Type","", "Set Channel 0 Input type", 0,31,0,,,,,,,,,; Enum303 = 0,"4 to 20 mA", 1,"0 to 20 mA", 2,"-10V to +10V",3,"0 to 10V",4,"1 to 5V", 5,"0 to 5V", 6,"-100mV to +100mV", 7,"-50mV to +50mV", 8, "Type J TC", 9,"Type K TC", 10,"Type T TC", 11,"Type E TC", 12,"Type R TC", 13,"Type S TC", 14,"Type B TC", 15,"Type N TC", 16,"Type C TC", 17,"100 Pt 385", 18,"200 Pt 385", 19,"500 Pt 385", 20,"1000 Pt 385", 21,"100 Pt 3916", 22,"200 Pt 3916", 23,"500 Pt 3916",24, "1000 Pt 3916", 25, "10 Cu 426", 26, "120 Ni 618", 27, "120 Ni 672", 28, "604 NiFe 518", 29, "150 Ohm", 30,"1000 Ohm", 31, "3000 Ohm"; Param304= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 0 Input Data Format","", "Set Channel 0 Data Format", 0,4,0,,,,,,,,,; Enum304 = 0,"Engineering Units", 1,"Engineering Units X10",2,"Raw/Proportional", 3,"Scaled for PID", 4,"Percent Range"; Param305= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 0 Cyclic Lead Comp.","", "Disable Channel 0 Lead Comp.", 0,1,0,,,,,,,,,; Enum305 = 0,"Enable", 1,"Disable"; Param306= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 0 4 Wire RTD","", "Enable 4 Wire RTD", 0,1,0,,,,,,,,,; Enum306 = 0,"Disable", 1,"Enable"; $*********************************** $ Channel 1 configuration data $*********************************** Param400= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 1","", "Enable or Disable Channel 1", 0,1,0,,,,,,,,,; Enum400 = 0,"Enable", 1,"Disable"; Param401 = 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 1 Filter Frequency","", "Set Channel 1 Filter Frequency", 0,6,0, ,,,,,,,,; Enum401 = 2,"10 Hz", 0,"60 Hz", 1,"50 Hz", 3,"250 Hz",4,"500 Hz",5,"1 kHz"; Param402= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 1 Open Circuit","", "Set Channel 1 Open Circuit", 0,3,0,,,,,,,,,; Enum402 = 0,"Upscale", 1,"Downscale", 2,"Last State",3,"Zero"; Param403= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 1 Input Type","", "Set Channel 1 Input type", 0,31,0,,,,,,,,,; Enum403 = 0,"4 to 20 mA", 1,"0 to 20 mA", 2,"-10V to +10V",3,"0 to 10V",4,"1 to 5V", 5,"0 to 5V", 6,"-100mV to +100mV", 7,"-50mV to +50mV", 8, "Type J TC", 9,"Type K TC", 10,"Type T TC", 11,"Type E TC", 12,"Type R TC", 13,"Type S TC", 14,"Type B TC", 15,"Type N TC", 16,"Type C TC", 17,"100 Pt 385", 18,"200 Pt 385", 19,"500 Pt 385", 20,"1000 Pt 385", 21,"100 Pt 3916", 22,"200 Pt 3916", 23,"500 Pt 3916",24, "1000 Pt 3916", 25, "10 Cu 426", 26, "120 Ni 618", 27, "120 Ni 672", 28, "604 NiFe 518", 29, "150 Ohm", 30,"1000 Ohm", 31, "3000 Ohm"; Param404= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 1 Input Data Format","", "Set Channel 1 Data Format", 0,7,0,,,,,,,,,; Enum404 = 0,"Engineering Units", 1,"Engineering Units X10",2,"Raw/Proportional", 3,"Scaled for PID", 4,"Percent Range"; Param405= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 1 Cyclic Lead Comp.","", "Disable Channel 1 Lead Comp.", 0,1,0,,,,,,,,,; Enum405 = 0,"Enable", 1,"Disable"; Param406= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 1 4 Wire RTD","", "Enable 4 Wire RTD", 0,1,0,,,,,,,,,; Enum406 = 0,"Disable", 1,"Enable"; $*********************************** $ Channel 2 configuration data $*********************************** Param500= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 2","", "Enable or Disable Channel 1", 0,1,0,,,,,,,,,; Enum500 = 0,"Enable", 1,"Disable"; Param501 = 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 2 Filter Frequency","", "Set Channel 2 Filter Frequency", 0,6,0, ,,,,,,,,; Enum501 = 2,"10 Hz", 0,"60 Hz", 1,"50 Hz", 3,"250 Hz",4,"500 Hz",5,"1 kHz"; Param502= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 2 Open Circuit","", "Set Channel 2 Open Circuit", 0,3,0,,,,,,,,,; Enum502 = 0,"Upscale", 1,"Downscale", 2,"Last State",3,"Zero"; Param503= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 2 Input Type","", "Set Channel 2 Input type", 0,31,0,,,,,,,,,; Enum503 = 0,"4 to 20 mA", 1,"0 to 20 mA", 2,"-10V to +10V",3,"0 to 10V",4,"1 to 5V", 5,"0 to 5V", 6,"-100mV to +100mV", 7,"-50mV to +50mV", 8, "Type J TC", 9,"Type K TC", 10,"Type T TC", 11,"Type E TC", 12,"Type R TC", 13,"Type S TC", 14,"Type B TC", 15,"Type N TC", 16,"Type C TC", 17,"100 Pt 385", 18,"200 Pt 385", 19,"500 Pt 385", 20,"1000 Pt 385", 21,"100 Pt 3916", 22,"200 Pt 3916", 23,"500 Pt 3916",24, "1000 Pt 3916", 25, "10 Cu 426", 26, "120 Ni 618", 27, "120 Ni 672", 28, "604 NiFe 518", 29, "150 Ohm", 30,"1000 Ohm", 31, "3000 Ohm"; Param504= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 2 Input Data Format","", "Set Channel 2 Data Format", 0,7,0,,,,,,,,,; Enum504 = 0,"Engineering Units", 1,"Engineering Units X10",2,"Raw/Proportional", 3,"Scaled for PID", 4,"Percent Range"; Param505= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 2 Cyclic Lead Comp.","", "Disable Channel 2 Lead Comp.", 0,1,0,,,,,,,,,; Enum505 = 0,"Enable", 1,"Disable"; Param506= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 2 4 Wire RTD","", "Enable 4 Wire RTD", 0,1,0,,,,,,,,,; Enum506 = 0,"Disable", 1,"Enable"; $*********************************** $ Channel 3 configuration data $*********************************** Param600= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 3","", "Enable or Disable Channel 1", 0,1,0,,,,,,,,,; Enum600 = 0,"Enable", 1,"Disable"; Param601 = 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 3 Filter Frequency","", "Set Channel 3 Filter Frequency", 0,6,0, ,,,,,,,,; Enum601 = 2,"10 Hz", 0,"60 Hz", 1,"50 Hz", 3,"250 Hz",4,"500 Hz",5,"1 kHz"; Param602= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 3 Open Circuit","", "Set Channel 3 Open Circuit", 0,3,0,,,,,,,,,; Enum602 = 0,"Upscale", 1,"Downscale", 2,"Last State",3,"Zero"; Param603= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 3 Input Type","", "Set Channel 3 Input type", 0,31,0,,,,,,,,,; Enum603 = 0,"4 to 20 mA", 1,"0 to 20 mA", 2,"-10V to +10V",3,"0 to 10V",4,"1 to 5V", 5,"0 to 5V", 6,"-100mV to +100mV", 7,"-50mV to +50mV", 8, "Type J TC", 9,"Type K TC", 10,"Type T TC", 11,"Type E TC", 12,"Type R TC", 13,"Type S TC", 14,"Type B TC", 15,"Type N TC", 16,"Type C TC", 17,"100 Pt 385", 18,"200 Pt 385", 19,"500 Pt 385", 20,"1000 Pt 385", 21,"100 Pt 3916", 22,"200 Pt 3916", 23,"500 Pt 3916",24, "1000 Pt 3916", 25, "10 Cu 426", 26, "120 Ni 618", 27, "120 Ni 672", 28, "604 NiFe 518", 29, "150 Ohm", 30,"1000 Ohm", 31, "3000 Ohm"; Param604= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 3 Input Data Format","", "Set Channel 3 Data Format", 0,7,0,,,,,,,,,; Enum604 = 0,"Engineering Units", 1,"Engineering Units X10",2,"Raw/Proportional", 3,"Scaled for PID", 4,"Percent Range"; Param605= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 3 Cyclic Lead Comp.","", "Disable Channel 3 Lead Comp.", 0,1,0,,,,,,,,,; Enum605 = 0,"Enable", 1,"Disable"; Param606= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 3 4 Wire RTD","", "Enable 4 Wire RTD", 0,1,0,,,,,,,,,; Enum606 = 0,"Disable", 1,"Enable"; $*********************************** $ Channel 4 configuration data $*********************************** Param700= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 4","", "Enable or Disable Channel 1", 0,1,0,,,,,,,,,; Enum700 = 0,"Enable", 1,"Disable"; Param701 = 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 4 Filter Frequency","", "Set Channel 4 Filter Frequency", 0,6,0, ,,,,,,,,; Enum701 = 2,"10 Hz", 0,"60 Hz", 1,"50 Hz", 3,"250 Hz",4,"500 Hz",5,"1 kHz"; Param702= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 4 Open Circuit","", "Set Channel 4 Open Circuit", 0,3,0,,,,,,,,,; Enum702 = 0,"Upscale", 1,"Downscale", 2,"Last State",3,"Zero"; Param703= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 4 Input Type","", "Set Channel 4 Input type", 0,31,0,,,,,,,,,; Enum703 = 0,"4 to 20 mA", 1,"0 to 20 mA", 2,"-10V to +10V",3,"0 to 10V",4,"1 to 5V", 5,"0 to 5V", 6,"-100mV to +100mV", 7,"-50mV to +50mV", 8, "Type J TC", 9,"Type K TC", 10,"Type T TC", 11,"Type E TC", 12,"Type R TC", 13,"Type S TC", 14,"Type B TC", 15,"Type N TC", 16,"Type C TC", 17,"100 Pt 385", 18,"200 Pt 385", 19,"500 Pt 385", 20,"1000 Pt 385", 21,"100 Pt 3916", 22,"200 Pt 3916", 23,"500 Pt 3916",24, "1000 Pt 3916", 25, "10 Cu 426", 26, "120 Ni 618", 27, "120 Ni 672", 28, "604 NiFe 518", 29, "150 Ohm", 30,"1000 Ohm", 31, "3000 Ohm"; Param704= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 4 Input Data Format","", "Set Channel 4 Data Format", 0,7,0,,,,,,,,,; Enum704 = 0,"Engineering Units", 1,"Engineering Units X10",2,"Raw/Proportional", 3,"Scaled for PID", 4,"Percent Range"; Param705= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 4 Cyclic Lead Comp.","", "Disable Channel 4 Lead Comp.", 0,1,0,,,,,,,,,; Enum705 = 0,"Enable", 1,"Disable"; Param706= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 4 4 Wire RTD","", "Enable 4 Wire RTD", 0,1,0,,,,,,,,,; Enum706 = 0,"Disable", 1,"Enable"; $*********************************** $ Channel 5 configuration data $*********************************** Param800= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 5","", "Enable or Disable Channel 1", 0,1,0,,,,,,,,,; Enum800 = 0,"Enable", 1,"Disable"; Param801 = 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 5 Filter Frequency","", "Set Channel 5 Filter Frequency", 0,6,0, ,,,,,,,,; Enum801 = 2,"10 Hz", 0,"60 Hz", 1,"50 Hz", 3,"250 Hz",4,"500 Hz",5,"1 kHz"; Param802= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 5 Open Circuit","", "Set Channel 5 Open Circuit", 0,3,0,,,,,,,,,; Enum802 = 0,"Upscale", 1,"Downscale", 2,"Last State",3,"Zero"; Param803= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 5 Input Type","", "Set Channel 5 Input type", 0,31,0,,,,,,,,,; Enum803 = 0,"4 to 20 mA", 1,"0 to 20 mA", 2,"-10V to +10V",3,"0 to 10V",4,"1 to 5V", 5,"0 to 5V", 6,"-100mV to +100mV", 7,"-50mV to +50mV", 8, "Type J TC", 9,"Type K TC", 10,"Type T TC", 11,"Type E TC", 12,"Type R TC", 13,"Type S TC", 14,"Type B TC", 15,"Type N TC", 16,"Type C TC", 17,"100 Pt 385", 18,"200 Pt 385", 19,"500 Pt 385", 20,"1000 Pt 385", 21,"100 Pt 3916", 22,"200 Pt 3916", 23,"500 Pt 3916",24, "1000 Pt 3916", 25, "10 Cu 426", 26, "120 Ni 618", 27, "120 Ni 672", 28, "604 NiFe 518", 29, "150 Ohm", 30,"1000 Ohm", 31, "3000 Ohm"; Param804= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 5 Input Data Format","", "Set Channel 5 Data Format", 0,7,0,,,,,,,,,; Enum804 = 0,"Engineering Units", 1,"Engineering Units X10",2,"Raw/Proportional", 3,"Scaled for PID", 4,"Percent Range"; Param805= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 5 Cyclic Lead Comp.","", "Disable Channel 5 Lead Comp.", 0,1,0,,,,,,,,,; Enum805 = 0,"Enable", 1,"Disable"; Param806= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 5 4 Wire RTD","", "Enable 4 Wire RTD", 0,1,0,,,,,,,,,; Enum806 = 0,"Disable", 1,"Enable"; $*********************************** $ Channel 6 configuration data $*********************************** Param900= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 6","", "Enable or Disable Channel 1", 0,1,0,,,,,,,,,; Enum900 = 0,"Enable", 1,"Disable"; Param901 = 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 6 Filter Frequency","", "Set Channel 6 Filter Frequency", 0,6,0, ,,,,,,,,; Enum901 = 2,"10 Hz", 0,"60 Hz", 1,"50 Hz", 3,"250 Hz",4,"500 Hz",5,"1 kHz"; Param902= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 6 Open Circuit","", "Set Channel 6 Open Circuit", 0,3,0,,,,,,,,,; Enum902 = 0,"Upscale", 1,"Downscale", 2,"Last State",3,"Zero"; Param903= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 6 Input Type","", "Set Channel 6 Input type", 0,31,0,,,,,,,,,; Enum903 = 0,"4 to 20 mA", 1,"0 to 20 mA", 2,"-10V to +10V",3,"0 to 10V",4,"1 to 5V", 5,"0 to 5V", 6,"-100mV to +100mV", 7,"-50mV to +50mV", 8, "Type J TC", 9,"Type K TC", 10,"Type T TC", 11,"Type E TC", 12,"Type R TC", 13,"Type S TC", 14,"Type B TC", 15,"Type N TC", 16,"Type C TC", 17,"100 Pt 385", 18,"200 Pt 385", 19,"500 Pt 385", 20,"1000 Pt 385", 21,"100 Pt 3916", 22,"200 Pt 3916", 23,"500 Pt 3916",24, "1000 Pt 3916", 25, "10 Cu 426", 26, "120 Ni 618", 27, "120 Ni 672", 28, "604 NiFe 518", 29, "150 Ohm", 30,"1000 Ohm", 31, "3000 Ohm"; Param904= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 6 Input Data Format","", "Set Channel 6 Data Format", 0,7,0,,,,,,,,,; Enum904 = 0,"Engineering Units", 1,"Engineering Units X10",2,"Raw/Proportional", 3,"Scaled for PID", 4,"Percent Range"; Param905= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 6 Cyclic Lead Comp.","", "Disable Channel 4 Lead Comp.", 0,1,0,,,,,,,,,; Enum905 = 0,"Enable", 1,"Disable"; Param906= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 6 4 Wire RTD","", "Enable 4 Wire RTD", 0,1,0,,,,,,,,,; Enum906 = 0,"Disable", 1,"Enable"; $*********************************** $ Channel 7 configuration data $*********************************** Param1000= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Channel 7","", "Enable or Disable Channel 1", 0,1,0,,,,,,,,,; Enum1000 = 0,"Enable", 1,"Disable"; Param1001 = 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 7 Filter Frequency","", "Set Channel 7 Filter Frequency", 0,6,0, ,,,,,,,,; Enum1001 = 2,"10 Hz", 0,"60 Hz", 1,"50 Hz", 3,"250 Hz",4,"500 Hz",5,"1 kHz"; Param1002= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 7 Open Circuit","", "Set Channel 7 Open Circuit", 0,3,0,,,,,,,,,; Enum1002 = 0,"Upscale", 1,"Downscale", 2,"Last State",3,"Zero"; Param1003= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 7 Input Type","", "Set Channel 7 Input type", 0,31,0,,,,,,,,,; Enum1003 = 0,"4 to 20 mA", 1,"0 to 20 mA", 2,"-10V to +10V",3,"0 to 10V",4,"1 to 5V", 5,"0 to 5V", 6,"-100mV to +100mV", 7,"-50mV to +50mV", 8, "Type J TC", 9,"Type K TC", 10,"Type T TC", 11,"Type E TC", 12,"Type R TC", 13,"Type S TC", 14,"Type B TC", 15,"Type N TC", 16,"Type C TC", 17,"100 Pt 385", 18,"200 Pt 385", 19,"500 Pt 385", 20,"1000 Pt 385", 21,"100 Pt 3916", 22,"200 Pt 3916", 23,"500 Pt 3916",24, "1000 Pt 3916", 25, "10 Cu 426", 26, "120 Ni 618", 27, "120 Ni 672", 28, "604 NiFe 518", 29, "150 Ohm", 30,"1000 Ohm", 31, "3000 Ohm"; Param1004= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 7 Input Data Format","", "Set Channel 7 Data Format", 0,7,0,,,,,,,,,; Enum1004 = 0,"Engineering Units", 1,"Engineering Units X10",2,"Raw/Proportional", 3,"Scaled for PID", 4,"Percent Range"; Param1005= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 7 Cyclic Lead Comp.","", "Disable Channel 4 Lead Comp.", 0,1,0,,,,,,,,,; Enum1005 = 0,"Enable", 1,"Disable"; Param1006= 0,,,, $ Reserved,link size, link path & descriptor 0xC6, 1, $ USINT "Chan. 7 4 Wire RTD","", "Enable 4 Wire RTD", 0,1,0,,,,,,,,,; Enum1006 = 0,"Disable", 1,"Enable"; [Assembly] ProxiedAssem101 ="Input Array",,,,,, 16,Param20, $ Channel 0 data 16,Param21, $ Channel 1 data 16,Param22, $ Channel 2 data 16,Param23, $ Channel 3 data 16,Param24, $ Channel 4 data 16,Param25, $ Channel 5 data 16,Param26, $ Channel 6 data 16,Param27, $ Channel 7 data 16,Param28, $ General/Open-circuit 16,Param29, $ Over/Under range error 16,Param30; $ CJC status ProxiedAssem4 ="Module Config Word0",,,,,, $------------ Word 0 ------------------ 1,Param100, $ Ch0 Temp Unit 1,Param101, $ Ch1 Temp Unit 1,Param102, $ Ch2 Temp Unit 1,Param103, $ Ch3 Temp Unit 1,Param104, $ Ch4 Temp Unit 1,Param105, $ Ch5 Temp Unit 1,Param106, $ Ch6 Temp Unit 1,Param107, $ Ch7 Temp Unit 1,Param108, $ CJC Temp Unit 3,0, $ Unused 1,Param109, $ CJC Weighted Profile 1,Param110, $ CJC Display 2,0, $ Unused $------------ Word 1 ------------------ 1,Param200, $ Ch0 Open circuit disable 1,Param201, $ Ch1 Open circuit disable 1,Param202, $ Ch2 Open circuit disable 1,Param203, $ Ch3 Open circuit disable 1,Param204, $ Ch4 Open circuit disable 1,Param205, $ Ch5 Open circuit disable 1,Param206, $ Ch6 Open circuit disable 1,Param207, $ Ch7 Open circuit disable 1,Param208, $ Ch0 (0 volt CJC adjust) 1,Param209, $ Ch1 (0 volt CJC adjust) 1,Param210, $ Ch2 (0 volt CJC adjust) 1,Param211, $ Ch3 (0 volt CJC adjust) 1,Param212, $ Ch4 (0 volt CJC adjust) 1,Param213, $ Ch5 (0 volt CJC adjust) 1,Param214, $ Ch6 (0 volt CJC adjust) 1,Param215, $ Ch7 (0 volt CJC adjust) $------------ Channel 0 ------------------ 1,Param300, $ Channel Enable 3,Param301, $ Filter Frequency 2,Param302, $ Open Circuit 5,Param303, $ Input Type 3,Param304, $ Data Format 1,Param305, $ Cyclic Lead Comp. 1,Param306, $ 4 Wire RTD enable $------------ Channel 1 ------------------ 1,Param400, $ Channel Enable 3,Param401, $ Filter Frequency 2,Param402, $ Open Circuit 5,Param403, $ Input Type 3,Param404, $ Data Format 1,Param405, $ Cyclic Lead Comp. 1,Param406, $ 4 Wire RTD enable $------------ Channel 2 ------------------ 1,Param500, $ Channel Enable 3,Param501, $ Filter Frequency 2,Param502, $ Open Circuit 5,Param503, $ Input Type 3,Param504, $ Data Format 1,Param505, $ Cyclic Lead Comp. 1,Param506, $ 4 Wire RTD enable $------------ Channel 3 ------------------ 1,Param600, $ Channel Enable 3,Param601, $ Filter Frequency 2,Param602, $ Open Circuit 5,Param603, $ Input Type 3,Param604, $ Data Format 1,Param605, $ Cyclic Lead Comp. 1,Param606, $ 4 Wire RTD enable $------------ Channel 4 ------------------ 1,Param700, $ Channel Enable 3,Param701, $ Filter Frequency 2,Param702, $ Open Circuit 5,Param703, $ Input Type 3,Param704, $ Data Format 1,Param705, $ Cyclic Lead Comp. 1,Param706, $ 4 Wire RTD enable $------------ Channel 5 ------------------ 1,Param800, $ Channel Enable 3,Param801, $ Filter Frequency 2,Param802, $ Open Circuit 5,Param803, $ Input Type 3,Param804, $ Data Format 1,Param805, $ Cyclic Lead Comp. 1,Param806, $ 4 Wire RTD enable $------------ Channel 6 ------------------ 1,Param900, $ Channel Enable 3,Param901, $ Filter Frequency 2,Param902, $ Open Circuit 5,Param903, $ Input Type 3,Param904, $ Data Format 1,Param905, $ Cyclic Lead Comp. 1,Param906, $ 4 Wire RTD enable $------------ Channel 7 ------------------ 1,Param1000, $ Channel Enable 3,Param1001, $ Filter Frequency 2,Param1002, $ Open Circuit 5,Param1003, $ Input Type 3,Param1004, $ Data Format 1,Param1005, $ Cyclic Lead Comp. 1,Param1006, $ 4 Wire RTD enable $------------ CJC Offsets ------------------ 16,0, $CH0 CJC Offset 16,0, $CH0 CJC Offset 16,0, $CH0 CJC Offset 16,0, $CH0 CJC Offset 16,0, $CH0 CJC Offset 16,0, $CH0 CJC Offset 16,0, $CH0 CJC Offset 16,0; $CH0 CJC Offset [Group] group1 = "channel 0",7,300,301,302,303,304,305,306; group2 = "channel 1",7,400,401,402,403,404,405,406; group3 = "channel 2",7,500,501,502,503,504,505,506; group4 = "channel 3",7,600,601,602,603,604,605,606; group5 = "channel 4",7,700,701,702,703,704,705,706; group6 = "channel 5",7,800,801,802,803,804,805,806; group7 = "channel 6",7,900,901,902,903,904,905,906; group8 = "channel 7",7,1000,1001,1002,1003,1004,1005,1006;